{"id":1554,"date":"2022-06-13T11:00:24","date_gmt":"2022-06-13T15:00:24","guid":{"rendered":"https:\/\/www.robbinsheating.com\/blog\/?p=1554"},"modified":"2022-06-11T19:49:49","modified_gmt":"2022-06-11T23:49:49","slug":"how-heat-pump-different-from-ac","status":"publish","type":"post","link":"https:\/\/www.robbinsheating.com\/blog\/heat-pump-service\/how-heat-pump-different-from-ac\/","title":{"rendered":"How a Heat Pump Is Different From an AC"},"content":{"rendered":"<p><span style=\"font-weight: 400;\"><img loading=\"lazy\" class=\"alignright size-medium wp-image-1555\" src=\"https:\/\/www.robbinsheating.com\/blog\/wp-content\/uploads\/2022\/06\/heat-pump-units-300x168.jpg\" alt=\"\" width=\"300\" height=\"168\" srcset=\"https:\/\/www.robbinsheating.com\/blog\/wp-content\/uploads\/2022\/06\/heat-pump-units-300x168.jpg 300w, https:\/\/www.robbinsheating.com\/blog\/wp-content\/uploads\/2022\/06\/heat-pump-units-768x430.jpg 768w, https:\/\/www.robbinsheating.com\/blog\/wp-content\/uploads\/2022\/06\/heat-pump-units.jpg 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>If you know the basics about heat pumps, then you can probably explain one of the big differences between a heat pump and an air conditioner right away: a heat pump works as both a cooling system and a heating system, where an air conditioner only cools.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">However, air conditioners and heat pumps are similar in many ways. They both use refrigerant to work, condensing and evaporating it in two sets of coils, and they have similar components (compressor, blower fan, exhaust fan, condensate drainage) and similar configurations (an interior air handler and exterior cabinet). Outwardly, it\u2019s difficult to tell the difference between them. But there obviously are differences\u2014because a heat pump does two jobs where an AC does one.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">So what makes an AC and heat pump different? We\u2019ll take a closer look below.<\/span><\/p>\n<p><!--more--><\/p>\n<h3><b>Heat pumps can change the direction refrigerant flows<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">This is the big difference that separates a heat pump from an air conditioner. Refrigerant is the heat transfer medium that allows an AC and heat pump to absorb heat from one set of coils and release it in the other. In an air conditioner, refrigerant only moves in one direction: it leaves the compressor as a hot gas and travels to the outside coils, where the refrigerant condenses and releases heat outdoors. The refrigerant then moves indoors, passing through a pressure relief valve that causes its temperature to drop further and turn into a cold liquid. This liquid moves through the indoor coil where it absorbs heat and cools the air. It then returns to the condenser.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Now imagine what happens if this process runs in reverse. The hot refrigerant would move first indoors and release heat from the coil, putting heat into the indoor air. The refrigerant would then move outdoors, changing into a cold liquid and absorbing heat through the outdoor coil before returning to the compressor. Essentially, switching the direction refrigerant moves causes the two sets of coils to swap jobs.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The key component necessary for a heat pump to change the direction of refrigerant flow is the reversing valve. This valve is located on the refrigerant line leaving the compressor, and depending on how it\u2019s set it will send the refrigerant either to the outdoor coil (cooling mode) or indoor coil (heating mode).\u00a0<\/span><\/p>\n<h3><b>Other important differences<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">There are several other differences in heat pump and AC construction. During winter, a heat pump\u2019s exterior coil will collect frost because of the water moisture that collects along its surface during evaporation. To remedy this, a heat pump has defrost controls. Periodically, the heat pump will change the direction of refrigerant flow so the coils give off heat and melt off the frost. It will then go back to normal heating mode.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A heat pump uses less refrigerant in heating mode. To store the excess refrigerant, a heat pump has a part called the suction line accumulator. This also helps to prevent cold refrigerant from flowing backward into the compressor (<\/span><i><span style=\"font-weight: 400;\">slugging<\/span><\/i><span style=\"font-weight: 400;\">), which can cause the compressor to break.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">If you have any questions about <\/span><a href=\"\/air-conditioning\/heat-pumps\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"font-weight: 400;\">heat pumps in Colorado Springs, CO<\/span><\/a><span style=\"font-weight: 400;\">, ask us!<\/span><\/p>\n<p style=\"text-align: center;\"><b>Robbins Heating &amp; Air Conditioning serves Colorado Springs and the surrounding area. <\/b><a href=\"\/contact\/schedule-service\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Call us for heat pump service\u2014installation, repair, replacement, maintenance.<\/b><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>What makes an AC and heat pump different? We\u2019ll take a closer look below.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[75],"tags":[89,218],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/posts\/1554"}],"collection":[{"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/comments?post=1554"}],"version-history":[{"count":2,"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/posts\/1554\/revisions"}],"predecessor-version":[{"id":1557,"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/posts\/1554\/revisions\/1557"}],"wp:attachment":[{"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/media?parent=1554"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/categories?post=1554"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.robbinsheating.com\/blog\/wp-json\/wp\/v2\/tags?post=1554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}